Comparison of two plasma collection systems for horses

Journal:Tierärztliche Praxis Großtiere
ISSN:1434-1220
Issue:2008: Issue 3 2008
Pages:199-203

Comparison of two plasma collection systems for horses

S. Lottner1, M. Ratzke1, R. Weiss2, A. Wehrend1
1Klinik für Geburtshilfe, Gynäkologie und Andrologie der Groß- und Kleintiere mit Tierärztlicher Ambulanz (Prof. Dr. A. Wehrend) und 2Institut für Hygiene und Infektionskrankheiten der Tiere (Prof. Dr. Dr. G. Baljer) der Justus-Liebig-Universität Gießen

Summary

Objective: Comparison of two commercially available plasma collection systems that operate based on erythrocyte sedimentation. Both systems were tested for plasma quality and practicability referring to horses. Material and methods: Five warmblood horses were used as blood-donors to compare system 1 (S1, Baxter Fenwal®, Maurepas, France) with system 2 (S2, “Plasma Collection Kit”, Arnolds, Shropshire, UK). Blood was collected with both systems from every horse. Subsequently plasma was extracted. Evaluated parameters comprised collection-time, obtained plasma volume, erythrocyte concentration and se - condary bacteriological contamination. Additionally costs and usability were assessed. Results: Due to the different preconditions blood-sampling time was shorter for system 1 (S1: 411 ± 13 s; S2: 2065 ± 545 s), bringing about comparatively small volumes of plasma (S1: 310 ± 37 g; S2: 990 ± 256 g). The concentration of erythrocytes was 0.11 ± 0.02 T/l (S1) and 0.18 ± 0.04 T/l (S2), respectively. One of the plasma samples taken with system 1 was mildly contaminated with Pseudomonas sp. and Acinetobacter sp. Conclusion: Both plasma systems are suitable for collecting plasma from horses. Clinical relevance: Due to the relatively short sampling time system 1 is well accepted by the horses. However, compared to system 2, only a small amount of plasma can be obtained per sampling. Concerning the longer sampling time of system 2, it is advisable to use it only for calm donor horses

Keywords

horse, blood collection, plasma collection, quality comparison

You may also be interested in...

1.

H. M. Clayton, A. D. White, L. J. Kaiser, S. Nauwelaerts, M. Lavagnino, N. C. Stubbs

VCOT - Veterinary and Comparative Orthopaedics and Traumatology 2008 21 3: 211-214

2.

M. Röcken1, G. Mosel1, C. Thum1, J. Rass1, L.-F. Litzke2

Tierärztliche Praxis Großtiere 2008 36 2: 124-130

3.

G. Stumpf1, M. Englisch2, A. Lindner3, M. Krüger1

Tierärztliche Praxis Großtiere 2008 36 2: 110-118



Articles

You've 15 Article(s) in your Basket.